REL12-BP04ReliabilityREL121 of 5 practices publishedReference content

Test resiliency using chaos engineering

Framework question: How do you test reliability?

Risk if not established
Medium
Framework verified
14 Nov 2026

AWS Well-Architected Framework — REL12-BP04 Test resiliency using chaos engineering

Executive summary

Why this practice matters

Run chaos experiments regularly, in production or an environment as close to it as possible, to learn how the workload copes with faults and unexpected load that nobody has planned for. Experiments are chosen from a prioritised list of failure modes, start from a measured steady state and a hypothesis, and are kept as code so successful ones become ongoing regression tests.

Business impact

  • Builds confidence that recovery designs will work in a real event.
  • Uncovers weaknesses that design reviews and known-behaviour tests miss.
  • Confirms that alerts fire and the right people are notified.
  • Turns lessons from past incidents into repeatable checks.

Assign

Accountable and responsible roles

Responsibilities are held separately from roles, so accountability type and typical roles are stated explicitly.

ResponsibilityAccountability type

Plan and run chaos experiments

Prioritise faults, define steady state and hypotheses, and run experiments with stop conditions.

Typical roles: SRE / Reliability Engineer, Quality Assurance / Test, SRE / Reliability Engineer, Quality Assurance / Test

responsible

Maintain experiments as code

Keep experiments in version control and run them in the pipeline and on a schedule.

Typical roles: DevOps Engineer, Cloud / Platform Engineer, DevOps Engineer, Cloud / Platform Engineer

responsible

Own resilience confidence

Agree acceptable experiment impact, approve production experiments, and make sure findings are fixed.

Typical roles: Service Owner, Operations Manager, Service Owner, Operations Manager

accountable

Assessment

Assessment and evidence state

States describe how far the practice has moved from intent to something continuously validated.

  1. 0

    Not Assessed

    No documented evaluation of the practice has been performed.

    Indicators

    • No one has examined how the workload would cope with faults that have not been planned for.
  2. 1

    Not Implemented

    The practice is absent or applied only ad hoc.

    Indicators

    • No fault injection takes place.
    • Resilience is assumed from the design.
  3. 2

    Partially Implemented

    The practice is applied to some workloads or components, with known gaps.

    Indicators

    • Experiments run occasionally in test environments, without a ranked fault list.
    • Results are not always recorded or acted on.
  4. 3

    Implemented

    The practice is applied consistently across defined scope, with evidence.

    Indicators

    • Experiments based on prioritised failure modes run regularly, with steady state, hypotheses and stop conditions.
    • Successful experiments are kept as code and rerun.
  5. 4

    Continuously Validated

    The practice is regularly tested and improved from measured results.

    Indicators

    • Experiments run close to production under realistic load, both in and outside the pipeline.
    • Findings measurably reduce incidents from untested faults.

Assessment dimensions

  • Fault prioritisation

    Practice-specific

    Absent · Partial · Operational and verified

  • Experiment design

    Practice-specific

    Absent · Partial · Operational and verified

  • Realistic conditions

    Practice-specific

    Absent · Partial · Operational and verified

  • Continuity and learning

    Practice-specific

    Absent · Partial · Operational and verified

Caution

Do not award maturity for occasional game days alone. Check that experiments target a prioritised list of failure modes, start from a defined steady state and hypothesis, are kept as code, and run regularly.

Standard

What you should be able to demonstrate

Statements a reviewer should be able to confirm from evidence, not from intent.

  • A prioritised list of faults to test is drawn from the resilience design, known issues and post-incident analyses.
  • Each experiment defines a measurable steady state and a hypothesis before faults are injected.
  • Experiments cover infrastructure, dependency and network faults, such as instance loss, failover, latency, packet loss and DNS failure.
  • Experiments are maintained as code and run both in the pipeline and outside deployments, including game days.
  • Stop conditions roll back an experiment automatically if customer impact goes beyond the agreed limit.

Trade-offs to hold in view

  • Experiments in or near production carry some risk to customers.
  • Production-like environments and game days cost time and money.
  • Keeping experiments current as the workload changes takes ongoing effort.

Assess

Questions to ask

Each question exposes the difference between an intention and an operating practice.

  • discovery

    Which failure modes from our recent incidents have we never deliberately recreated?

    Links past incidents to the experiment backlog.

    Usually asked by: SRE / Reliability Engineer, Operations Engineer

  • challenge

    What would happen to customers if a third-party dependency became unreachable for an hour?

    Probes failures beyond the team's direct control.

    Usually asked by: Architect, SRE / Reliability Engineer

  • evidence

    Can we show the steady state, hypothesis, stop conditions and outcome of our last chaos experiment?

    Requires structured, recorded experiments.

    Usually asked by: SRE / Reliability Engineer, Quality Assurance / Test

  • executive

    Are we confident our recovery design works, or have we only assumed it?

    Distinguishes verified resilience from belief.

    Usually asked by: Technology Executive, Service Owner

Evidence

Required and expected evidence

Reusable evidence definitions held once in the evidence library and referenced by every practice that relies on them. Each links to what good evidence looks like and to worked examples.

EVD-RISK-001coreReusable

Risk Register

A current, owned register of material risks relevant to a workload, initiative or decision, showing how each risk is assessed, treated, monitored and escalated.

Shows the prioritised failure modes that chaos experiments are designed to test.

Minimum expected content

  • Stable risk identifier and concise risk statement
  • Source, context or decision that gives rise to the risk
  • Affected workload, service, capability or business outcome
  • Likelihood and impact assessment using the organisation's agreed method
  • Risk owner responsible for ensuring the risk is actively managed
  • Planned treatment or mitigation actions, including action owners and target dates where applicable
  • Residual risk after current/planned treatment
  • Current status and trend or material change since the previous review
  • Next review date or review trigger
  • Decision or acceptance authority where residual risk requires explicit acceptance

Anti-patterns

  • A long list of generic risks with no connection to actual decisions, workloads or outcomes
  • Risk owner fields populated with teams or committees that cannot take action
  • Likelihood and impact scores copied forward without reviewing changed evidence
  • Mitigation actions with no owner, target or evidence of progress
  • Residual risk assumed to be accepted because a risk remains open
  • The register is updated for audits but is not used when material decisions are made

Review: Maintain continuously; review at material decisions, governance reviews, significant change and whenever assumptions, exposure or treatment status changes.

EVD-OPS-002supportingReusable

Operational Readiness Review

A structured record showing whether a workload or service is ready to operate safely and reliably, what gaps or conditions remain, who owns them and what decision was made.

Shows the resilience mechanisms and past incident lessons that experiments must confirm.

Minimum expected content

  • Workload or service, scope, environment and review date
  • Named review owner and participating roles
  • Readiness criteria and results across monitoring, incident response, recovery, security, configuration, performance, documentation/training and dependencies
  • Identified gaps, exceptions and material risks
  • Actions, owners and due dates
  • Overall readiness decision or status, including any conditions
  • Approval or acceptance record and next review date where applicable

Anti-patterns

  • Checklist completed as a documentation exercise with no supporting evidence
  • Generic organisation-wide checklist copied without workload-specific acceptance criteria
  • All items marked complete despite known unresolved risks
  • No distinction between required evidence, reviewer judgement and remediation actions
  • A readiness status with no named decision owner
  • A historic ORR reused after material architecture, dependency or operating-model change

Review: Before production launch and material operational change; repeat periodically where continuing assurance is required.

Diagnosis

Common evidence gaps

  • Design never verified

    The workload is designed for resilience, but nobody checks how it behaves as a whole when faults occur.

  • Unrealistic conditions

    Experiments never run under real-world conditions or expected load.

  • One-off experiments

    Experiments are not kept as code, so they decay as the workload changes.

  • Incidents ignored

    Past post-incident analyses are not used to choose which faults to test.

Implementation

Implementation guidance

List and rank failure modes

Use the resilience design, a failure modes and effects analysis and past incidents to list faults, then rank them by how often they happen and how much they would hurt.

Define steady state first

Confirm the workload is healthy and describe normal behaviour as measurable output, such as throughput, success rate and response time.

Form a hypothesis and guardrails

State how the workload should react to the fault and set stop conditions that end the experiment if impact exceeds the limit.

Inject realistic faults

Combine component faults to mimic wider disruptions, block access to third-party dependencies, and add latency or dropped messages to test degraded behaviour.

Keep experiments running

Store experiments as code, run them regularly both in the pipeline and on scheduled game days, and hold a blameless review of each result.

Measure

Measurements

  • High-priority failure modes covered by an experiment
  • Experiments run per period, inside and outside the pipeline
  • Weaknesses found and resolved
  • Experiments stopped by guardrails

Related

Outcomes and practices

Business outcomes

    Practices